Panel User Guide Issue 1.4 4000 Digital Series II
Page 122 STA0380
For a Supervisor Panel fitted with a PDE4537 options card, a button or switch connected to GPI #3 can
be used to terminate a mimic/control session. Any switch transition detected on GPI #3 causes the
current session to be terminated.
4.12.4 Supervisor Facilities
When a valid target panel has been selected, the Supervisor Panel display and LED Status switch over
to mimic the current display and LED Status of the target panel.
4.12.4.1 Key Presses
All Supervisor Panel key presses, except for the auxiliary volume control pot switch (i.e. INFO key), are
transferred to the target panel, as if pressed at the target panel. The target panel responds to local key
presses and key presses transferred from the Supervisor Panel.
When the same key is pressed or held simultaneously on the Supervisor and target panels, the first key
action to be detected causes the key press action to take effect. The last key to be released causes the
release to take effect.
4.12.4.2 Cross-point Level Control
Cross-point level control affects the level of incoming audio routes to the target and Supervisor panels.
A Supervisor Panel and target panel both have the ability to control the cross-point levels.
The cross-point level is determined by the 'last moved' rotary encoder. For example, if the Supervisor
Panel is used to turn a cross-point level down to 0.0, then the target panel is used to turn the same cross-
point level up to 10.0, a further movement of the Supervisor Panel control 'jumps' the level back down to
0.0 again. The level bar indicator on the Supervisor and target panel keys always shows the actual cross-
point level.
When using a Supervisor Panel to control either a PD4221 or PD4211 target panel type (i.e. LCD key
panels with a single rotary encoder above the REPLY key), the rotary encoders above the supervisor
panel DAKs do not control the cross-point levels of the associated DAK. The supervisor panel mimics
the target panel operation, so the rotary encoder above the REPLY key needs to be pressed to invoke
cross-point level control mode on the target panel. Cross-point level control can then be performed at
the supervisor panel by pressing the desired DAK and turning the REPLY key rotary encoder.
4.12.5 Audio Monitoring In Supervisor Mode
4.12.5.1 Supervisor Panel
All audio routes to and from a Supervisor Panel, prior to the selection of a target panel, are removed
while the mimic/control session is active. The routes are restored when the mimic/control session is
terminated.
New calls to a Supervisor Panel are not routed to or indicated to the Supervisor Panel until after the
mimic/control session has been terminated.
4.12.5.2 Target Panel
New calls to a target panel are duplicated at the Supervisor Panel unless the rack set-up inhibits the
routes (e.g. permanently open cross-point).
4.12.5.3 Indication To Third Parties
A third party panel making calls to the target or Supervisor panel during a mimic/control session will not
receive any indication that the destination they are calling is currently in a mimic/control session.
4.12.5.4 System and Panel Resets
After a red button reset the Supervisor and target panels maintain the mimic/control session.