Panel User Guide Issue 1.4 4000 Digital Series II
Page 186 STA0380
6.4.4 Shift Page
The shift page increases the number of DAKs on the panel from 14 to 26 ( Note the REPLY Key is not
shifted ). The shift page is selected when the SHIFT button is pressed. The shift button LED is on while
the shift page is selected and the display above the DAKs shows the mnemonics for the DAKs on the
shift page.
Assignments can be made to DAKs on the shift page in SOFT Mode and the listen levels of DAKs on
the shift page can be adjusted in Level Control Mode. Each page number has its own shift page.
The shift page can be selected while in any of the three panel operating modes (Master Level Control,
Level Control and SOFT).
The 'main' page returns after the shift button is de-selected. The shift page LED is cleared and the
display shows the mnemonics of the DAKs on the 'main' page.
6.4.5 Diagnostic Page
The diagnostics page supplies status information about the panel. The information available consists of:
System number panel belongs to
Directory entry corresponding to panel
Software version running on panel
Map name of configuration on panel
Local control output states of the headset, loudspeaker and microphone
Remote system status
The diagnostic page is displayed after the SOFT pushbutton is pressed and held for over a second. The
SOFT Pushbutton LED will light. Initially the Vitec Group Communications copyright message is
displayed for 1 second, this is followed by the Diagnostic Page display. The page is only displayed whilst
the SOFT pushbutton is pressed. When the button is released the panel returns to Master Level Control
Mode.
The Diagnostics Page is not displayed when the SOFT pushbutton is pressed to exit SOFT Mode.
While the diagnostic page is displayed, the LEVEL button can be pressed to show the current crosspoint
level settings. A value in the range 0.0 to 10.0 is shown above each of the configured DAKs.
6.4.6 LED Display Brightness Control
The brightness of the Alphanumeric LED Displays above the DAKs and the Rotary Encoder can be
adjusted. Pressing and holding the SOFT Pushbutton for over a second when in Master Level Control
Mode, displays the Diagnostic Page. While still pressing the SOFT Pushbutton, press the corresponding
DAKs that have a numerical legend to enter a number in the range 101 to 110, this adjusts the brightness
of the displays; 110 corresponds to the brightest setting.
6.4.7 Panel Feature Summary
This section highlights the main feature differences between the PD4217 panel and the 4000 Series II
Control Panels.